Background:
2SKC series liquid ring vacuum pumps(double stage liquid ring vacuum pump) are used for exhausting and compressing air and other noncorrosive, water-insoluble and solid particle-free gases so as to create vacuum and pressure in closed containers. A little liquid is allowed in the gas.
2SKC series liquid ring vacuum pumps have included secondary impellers and pump cavities to increase vacuum by serial connection. The pumps have high exhaustion capacity under high vacuum degree. The 2SKC water ring pumps can also be connected with air ejector, the limiting vacuum combined with air ejector can be up to -740mmhg, ( -0.098Mpa), and the absolute pressure is about 2660pa. Furthermore, the 2SKC water ring vacuum pump can be combined with Roots vacuum pumps as well to combine liquid ring-roots vacuum unit with a wider application range due to the high ultimate vacuum of 0.5Pa.
Main features:
Compact structure and convenient maintenance;
Wide application range, which applicable for gas with vapor or flammable, explosive, containing a little dust and a little liquid gas.
Low maintenance expense since water is the main operating medium;
Applicable in severe environments.
2SKC LRVP performance parameter:
型号
Model |
抽气量m3/min | 极限压力
MPa (mmHg) |
Motor
电机功率 KW |
转速
(转/分) r.p.m |
供水量
(升/分) L/min |
吸排气
口径 Diameter |
|
最大气量Max | 吸入压力为-0.093MPa时,
不小于 |
||||||
2SKC-0.4 | 0.4 | 0.25 | -0.096(-725) | 2.2 | 2840 | 3~5 | G1″ |
2SKC-0.8 | 0.8 | 0.5 | -0.096(-725) | 3 | 2880 | 5~8 | G1″ |
2SKC-1.5 | 1.5 | 0.9 | -0.096(-725) | 4 | 1440 | 10~15 | φ40 |
2SKC-3 | 3 | 2 | -0.097(-730) | 7.5 | 1440 | 15~20 | φ40 |
2SKC-6 | 6 | 4 | -0.098(-735) | 15 | 1450 | 25~35 | φ70 |
2SKC-12 | 12 | 8 | -0.098(-735) | 22 | 970 | 40~50 | φ100 |
2SKC-20 | 20 | 14 | -0.098(-735) | 45 | 740 | 60~80 | φ125 |
2SKC-30 | 30 | 20 | -0.098(-735) | 55 | 740 | 70~90 | φ125 |
Note:
The 2SKC performance curve is obtained under the standard condition.
2SKC series pumps are suitable to deal with high vacuum only, but if it is long-term low vacuum or wide working range, the motor should have a higher power.